| WANG Dong,SHA Xin,TAN Shengzhi.Study on the effect of posterior corrective internal fixation using Dynesys system on coronal balance in Lenke 5 adolescent idiopathic scoliosis[J].Chinese Journal of Spine and Spinal Cord,2026,(9):1025-1032. |
| Study on the effect of posterior corrective internal fixation using Dynesys system on coronal balance in Lenke 5 adolescent idiopathic scoliosis |
| Received:December 19, 2025 Revised:May 21, 2026 |
| English Keywords:Adolescent idiopathic scoliosis Dynesys system Posterior corrective internal fixation Coronal balance |
| Fund: |
|
| Hits: 36 |
| Download times: 0 |
| English Abstract: |
| 【Abstract】 Objectives: To explore the impact of posterior corrective internal fixation with Dynesys system on the coronal balance of spine in Lenke type 5 adolescent idiopathic scoliosis(AIS) patients. Methods: A retrospective analysis was conducted on the imaging data of 13 patients with Lenke type 5 AIS(Risser sign>Ⅲ, correction rate in bending position>70%) who underwent posterior instrumentation with Dynesys system at our hospital from November 2019 to August 2024. Preoperative, postoperative 1 week(first follow-up), and final follow-up main curve Cobb angle, proximal secondary curve Cobb angle, shoulder angle(SA), lower instrumented vertebra(LIV) tilt angle, and C7PL-CSVL(distance between the C7 plumb line and the sacral midline plumb line) were measured and compared to analyze the influence of surgery at different postoperative time points on coronal parameters. Results: All 13 patients were reexamined within one week after operation; 11 patients completed the final follow-up, while two patients failed to complete the final follow-up due to personal reasons. The follow-up duration was 17.5±13.6 months(range: 6-60 months). One week post-surgery, the main curve Cobb angle decreased from 43.4°±9.1° pre-surgery to 5.9°±4.7°, with an average correction rate of 86.5%; the proximal secondary curve Cobb angle decreased from 22.3°±10.1° to 5.9°±5.8°, with an average correction rate of 73.8%. There were statistically significant differences in the above indicators between pre-surgery and 1 week post-surgery(P<0.001). C7PL-CSVL decreased from 2.3±1.2cm pre-surgery to 1.2±0.4cm one week post-surgery; LIV tilt decreased from 16.5°±4.6° pre-surgery to 4.9°±3.2° one week post-surgery, both differences were statistically significant(P<0.001). SA changed from 2.9°±1.8° pre-surgery to 2.4°±2.1° one week post-surgery, with no statistically significant difference(P=0.345). Final follow-up(n=11) compared with 1 week post-surgery, the main curve Cobb angle had an average loss of 3.1°(final value of 9.0°), and the proximal secondary curve Cobb angle had an average loss of 4.1°(final value of 10.0°); LIV tilt angle increased by an average of 1.1°(final value of 6.0°). Despite a certain degree of angle loss, the differences in the above three indicators at the final follow-up compared to the pre-surgery baseline were still statistically significant(P=0.004, P<0.001, P<0.001). SA was 0.7°±0.9° at the final follow-up, with a statistically significant difference compared to pre-surgery(P<0.001). C7PL-CSVL remained at 1.2±0.5cm at the final follow-up, and no cases of coronal plane decompensation(defined as C7PL-CSVL>2.0cm or deterioration>1cm compared to immediate post-surgery) were observed in this group. Conclusions: Posterior corrective internal fixation using Dynesys system in treating Lenke type 5 AIS with Risser sign>Ⅲ and correction rate in bending position>70% can achieve satisfactory immediate corrective effects, and the coronal plane balance parameters remain well-maintained during the follow-up period. |
| View Full Text View/Add Comment Download reader |
| Close |
|
|
|
|
|