ZU Dan,HAI Yong,YUN Cai.Adjacent segment range of motion after different insertion depth of lumbar interspinous dynamic stabilization device(Coflex): a biomechanical study[J].Chinese Journal of Spine and Spinal Cord,2014,(10):933-937.
Adjacent segment range of motion after different insertion depth of lumbar interspinous dynamic stabilization device(Coflex): a biomechanical study
Received:July 19, 2014  Revised:August 16, 2014
English Keywords:Lumbar vertebrae  Adjacent segment  Internal fixators  Prosthesis implantation  Biomechanics
Fund:北京市自然科学基金(项目编号:7112056)
Author NameAffiliation
ZU Dan Department of Orthopaedics, Shijingshan Teaching Hospital of Capital Medical University, Beijing Shijingshan Hospital, Beijing, 100043, China 
HAI Yong 首都医科大学附属北京朝阳医院骨科 100020 北京市 
YUN Cai 首都医科大学石景山教学医院北京市石景山医院骨科 100043 北京市 
鲁世保  
刘玉增  
李士春  
李钦亮  
Hits: 2985
Download times: 2378
English Abstract:
  【Abstract】 Objectives: To evaluate the lumbar adjacent segment range of motion after different insertion depth of lumbar interspinous dynamic stabilization device(Coflex). Methods: Six fresh adult human cadaveric lumbar spine specimens(L1-L5) were fixed in a material testing system(MTS) by embedding to clamps with L1 and L5 vertebrae. L3/4 of each specimen was operated. The L2, L3, L4, L5 vertebra was inserted one spacer respectively which was used to record the range of motion(ROM) of the adjacent segments(L2/3, L4/5). Each lumbar spine specimen was tested according to the loading sequence at 3 groups: intact(keeping lumbar ligament and facet joint intact) group, 5mm insertion(distance between apex of U-shaped Coflex and dural sac was 5mm) group and 0mm insertion(distance was 0mm) group. Each lumbar spine specimen was loaded with pure moments of 8N·m according to a loading sequence consisting of flexion, extension, left/right lateral bend?鄄ing, left/right axial rotation and the ROM of adjacent segment was recorded. Adjacent segments(L2/3, L4/5) ROM of 3 groups in 6 directions was analyzed respectively with one-way ANOVA test and multiple comparisons were based on LSD method. Results: In L2/3 segment: the mean ROM of 3 groups was equal in flexion, extension, left/right lateral bending, left/right axial rotation(intact group: 4.23°±0.25°, 3.56°±0.14°, 3.07°±0.12°, 3.34°±0.08°, 2.53°±0.16°, 2.44°±0.11°; 5mm insertion group: 4.40°±0.21°, 3.64°±0.14°, 3.09°±0.11°, 3.35°±0.07°, 2.54°±0.16°, 2.46°±0.10°; 0mm insertion group: 4.47°±0.20°, 3.72°±0.16°, 3.14°±0.10°, 3.38°±0.08°, 2.58°±0.15°, 2.49°±0.12°), and there were no significant differences among 3 groups(all P>0.05). In L4/5 segment: the mean ROM of 3 groups was equal in flexion, extension, left/right lateral bending, left/right axial rotation (intact group: 3.80°±0.28°, 3.45°±0.11°, 3.25°±0.11°, 3.28°±0.13°, 2.44°±0.11°, 2.42°±0.11°; 5mm insertion group: 3.86°±0.28°, 3.52°±0.11°, 3.28°±0.09°, 3.31°±0.05°, 2.50°±0.07°, 2.46°±0.09°; 0mm insertion group: 4.47°±0.20°, 3.72°±0.16°, 3.14°±0.10°, 3.38°±0.08°, 2.58°±0.15°, 2.49°±0.12°), and there were no significant differences among 3 groups(all P>0.05). Conclusions: The adjacent segments after different insertion depth(when distance between apex of U-shaped Coflex and dural sac was or less than 5mm) of lumbar interspinous dynamic stabilization device(Coflex) allow no significantly more motion than the intact specimen in flexion, extension, left/right lateral bending, left/right axial rotation.