LV You,ZHANG Daming,LI Rui.Study of reliability and reproducibility of AO,Denis and TLICS classification systems for thoracolumbar fracture[J].Chinese Journal of Spine and Spinal Cord,2011,(7):566-568.
Study of reliability and reproducibility of AO,Denis and TLICS classification systems for thoracolumbar fracture
Received:January 26, 2011  Revised:March 03, 2011
English Keywords:Thoracolumbar fracture  TLICS  AO classification  Denis classification  Consistency test
Fund:
Author NameAffiliation
LV You The Third Department of OrthopaedicsBeijing DCN Orthopaedic HospitalBeijing100143China 
ZHANG Daming 北京德尔康尼骨科医院骨三科 100143 北京市 
LI Rui 北京德尔康尼骨科医院骨三科 100143 北京市 
张学东  
贾 斌  
Hits: 4485
Download times: 3052
English Abstract:
  【Abstract】 Objective:To investigate and compare the reliability and reproducibility of AO,Denis and TLICS classification systems in the diagnosis of thoracolumbar fracture.Method:Thirty-one thoracolumbar fracture patients with complete clinical data and radiologic data(including X-ray films,CT and MRI) were enrolled.Six observers,who were orthopaedic surgeons,determined the classifications according to AO,Denis and TLICS systems respectively.The classification was repeated three months later.The Cohen Kappa test was used to determine inter-observer reliability and intra-observer reproducibility.Result:The average inter-observer Kappa values for AO,Denis and TLICS Systems were 0.517,0.639 and 0.713 respectively.And the intra-observer agreements were 0.766,0.832 and 0.804 respectively.Conclusion:Among the three classification systems,TLICS system has the greatest reliability and reproducibility,and thus has more value in clinical practice.