.Evaluation of thoracic pedicle screw placement position by computed tomography[J].Chinese Journal of Spine and Spinal Cord,2005,(4):.
Evaluation of thoracic pedicle screw placement position by computed tomography
SendTime  LastModifyTime
English Keywords:Thoracic spine,Pedicle,Screw,Computed tomography
Fund:
毛克亚  王岩  张永刚  刘郑生  肖嵩华  刘保卫
解放军总医院骨科 100853北京市复兴路28号 (毛克亚,王岩,张永刚,刘郑生,肖嵩华)
,解放军总医院骨科 100853北京市复兴路28号(刘保卫)
Hits: 3482
Download times: 2910
English Abstract:
  Objective:To evaluate the accuracy of thoracic pedicle screw placement by computed tomography.Method:Thoracic pedicle screws were inserted in 37 patients subjected to thoracic pedicle screw fixation,and postoperative computed tomography(CT) were scanned t