.Different lumbar fusion methods for management of instability of lower lumbar spine: a biomechanical study in vitro[J].Chinese Journal of Spine and Spinal Cord,2002,(5):.
Different lumbar fusion methods for management of instability of lower lumbar spine: a biomechanical study in vitro
SendTime  LastModifyTime
English Keywords:Lumbar spine,Fusion,Biomechanics,Stability,Fatigue
Fund:
丁宇  阮狄克
海军总医院骨科 100037北京市 (丁宇)
,海军总医院骨科 100037北京市(阮狄克)
Hits: 2876
Download times: 131
English Abstract:
  Objective:To investigate different lumbar fusion methods and fatigue loading in the management of instability of lower lumbar spine biomechanically in vitro.Method:Nine fresh human cadaver specimens from L1to sacrum were used in this study.Each intact lum
View Full Text  View/Add Comment  Download reader