李 野,刘景臣,武云涛,张云峰,公伟权,陈许冬,朱庆三.C6、C7椎弓根置钉的应用解剖学研究[J].中国脊柱脊髓杂志,2013,(7):633-637.
C6、C7椎弓根置钉的应用解剖学研究
中文关键词:  颈椎  C6  C7  椎弓根  螺钉  解剖
中文摘要:
  【摘要】 目的:通过对C6、C7椎弓根的解剖学测量,设计一种以“峡部”为参考的C6、C7椎弓根置钉的方法。方法:15具经福尔马林浸泡的成人颈椎标本,不分性别、年龄,排除畸形及破坏。取C6、C7共30个椎体。先测量椎弓根宽度(PW)、椎弓根高度(PH)。将C6、C7侧块中的一部分定义为“峡部”,即过上关节突下缘最低点、下关节突上缘最高点的水平线与过上关节突内外侧缘的垂线所围成区域。过上关节突内外侧缘之间划两条垂线,将“峡部”分为3等份,中份为“峡部”的后侧面,外份为“峡部”的后外侧面。取过横突根部中点的水平线与过“峡部”中外1/3垂线的交点为螺钉的进钉点。选择3.5mm直径及合适长度的螺钉,直视下沿椎弓根中轴线方向置入,使螺钉中轴线与椎弓根中轴线重合,螺钉前端穿出椎体或上终板。沿椎弓根中轴线的水平面锯开标本,可看到螺钉处在椎弓根中轴线上。螺钉在水平面上与“峡部”的后外侧面形成的角为横向角(E角);螺钉在矢状面上与“峡部”后侧面形成的角为纵向角(F角)。测量椎弓根钉道全长(FSC)。对数据进行t检验及类聚分析。结果:各指标同一节段左右侧数据比较无统计学差异(P>0.05),故将同节段左右侧数据合并后进行统计分析。C6的PW为6.12±0.78mm,PH为7.48±0.81mm;C7的PW为6.85±0.73mm,PH为8.03±0.38mm;PW与PH均为C6
Applied anatomical study on pedicle screw placement in C6 and C7
英文关键词:Cervical vertebra  C6  C7  Pedicle  Screw  Anatomic
英文摘要:
  【Abstract】 Objectives: To investigate pedicle screw placement in C6 and C7, and to design C6 and C7 pedicle placement based on the isthmus as anatomic mark. Methods: 15 adult cervical specimens were used regardless of gender or age. No deformity or damage to the specimen was noted. Only the C6 and C7 specimens were used. Pedicle width(PW) and pedicle height(PH) were measured. The area below the lower edge of the superior articular process, above the upper edge of the inferior articular process, and between the medial and lateral edges of the superior articular process of the same cervical segment was defined as the isthmus respectively. The isthmus was divided into three equal parts, and two vertical lines were drawn, with the medial third as the posterior plane of the isthmus and lateral third as the posterolateral plane of the isthmus. The entry point was chosen as the intersection of the horizontal line through the midpoint of the transverse process root and the vertical line through the posterolateral plane and the posterior plane of the isthmus. The screw with a diameter of 3.5mm and suitable length was inserted to ensure the end of screw to reach the cortical bone. The axis of screws was consistent with the axis of pedicle. The angle formed by the axis of cervical pedicle screw on the horizontal plane to the posterolateral plane of isthmus was defined as the transverse angle of the inserted screw(E). The angle formed by the axis of cervical pedicle screw on the sagittal plane to the posterior plane of isthmus was defined as the vertical angle of the inserted screw(F). The two angles and the full length of pedicle screw channel(FSC) were measured. Results: There was no statistical significance as for the measurement between left side and right side at the same segment(P>0.05), therefore the bilateral data were combined. PW and PH of C6 was 6.12±0.78mm and 7.48±0.81mm respectively. PW and PH of C7 was 6.85±0.73mm and 8.03±0.38mm respectively. C6′s PW and PH were less than C7′s(P<0.05), while at the same segment PW was less than PH(P<0.05). Using Hierarchical cluster analysis, the results showed that E angle tended to be two kinds as E1 and E2. The E1, E2, F angle, and FSC between C6 and C7 were not significantly different(P>0.05), the data of the same index in C6 and C7 were combined, and FSC was 30.83±0.91mm, E1 angle was 89.61°±1.24°, E2 was 59.71°±1.10°, F angle was 75.86°±1.12°. Conclusions: The intersection of the horizontal line through the midpoint of the transverse process root and the vertical line through the mediolateral third of the isthmus can be used as the entry point for pedicle screw placement, and the screw channel should be along the pedicle axis and referenced to the E and F angle. This method is practical and reliable.
投稿时间:2012-10-26  修订日期:2013-02-02
DOI:
基金项目:
作者单位
李 野 吉林大学白求恩第一医院脊柱外科 130021长春市 
刘景臣 吉林大学白求恩第一医院脊柱外科 130021长春市 
武云涛 吉林大学白求恩第一医院脊柱外科 130021长春市 
张云峰  
公伟权  
陈许冬  
朱庆三  