汪 东,沙 鑫,谭胜芝,田 天,崔 凯,刘 涛,李 源,郑润龙,谭 荣.应用Dynesys系统行后路矫形内固定术对Lenke 5型青少年特发性脊柱侧凸患者冠状面平衡的影响[J].中国脊柱脊髓杂志,2026,(9):1025-1032.
应用Dynesys系统行后路矫形内固定术对Lenke 5型青少年特发性脊柱侧凸患者冠状面平衡的影响
Study on the effect of posterior corrective internal fixation using Dynesys system on coronal balance in Lenke 5 adolescent idiopathic scoliosis
投稿时间:2025-12-19  修订日期:2026-05-21
DOI:
中文关键词:  青少年特发性脊柱侧凸  Dynesys系统  后路矫形内固定  冠状面平衡
英文关键词:Adolescent idiopathic scoliosis  Dynesys system  Posterior corrective internal fixation  Coronal balance
基金项目:
作者单位
汪 东 解放军总医院第九医学中心脊柱二科 100101 北京市 
沙 鑫 解放军总医院第九医学中心脊柱二科 100101 北京市 
谭胜芝 解放军总医院第九医学中心脊柱二科 100101 北京市 
田 天  
崔 凯  
刘 涛  
李 源  
郑润龙  
谭 荣  
摘要点击次数: 135
全文下载次数: 0
中文摘要:
  【摘要】 目的:探讨应用Dynesys系统行后路矫形内固定术对Lenke 5型青少年特发性脊柱侧凸(adolescent idiopathic scoliosis,AIS)患者脊柱冠状面平衡的影响。方法:回顾性分析2019年11月~2024年8月于我院接受Dynesys系统后路矫形内固定治疗的13例Risser征>Ⅲ级、Bending位矫正率>70%的Lenke 5型AIS患者的影像学资料。测量术前、术后1周内(初次复查)及末次随访时主弯Cobb角、近端继发弯Cobb角、肩部倾斜角(shoulder angle,SA)、下端固定椎(lower instrumented vertebra,LIV)倾斜角和C7铅垂线与骶骨中垂线距离(C7PL-CSVL),通过术后1周及末次随访时的冠状面参数与术前测量结果进行对比,分析该手术在术后不同时间点对冠状面平衡相关参数的影响。结果:13例患者术后1周内均获得复查,11例患者完成随访,2例患者因个人原因未完成末次随访。本组患者随访时间为17.5±13.6个月(6~60个月)。术后1周,主弯Cobb角由术前43.4°±9.1°降至5.9°±4.7°,平均矫正率为86.5%;近端继发弯Cobb角由22.3°±10.1°降至5.9°±5.8°,平均矫正率为73.8%;相较于术前,差异均有统计学意义(P<0.001)。C7PL-CSVL由术前2.3±1.2cm 降至术后1周1.2±0.4cm;LIV倾斜角由术前16.5°±4.6°降至术后1周4.9°±3.2°,差异均有统计学意义(P<0.001)。SA由术前2.9°±1.8°变为术后1周2.4°±2.1°,差异无统计学意义(P=0.345)。末次随访时(n=11)与术后1周相比,主弯Cobb角平均丢失3.1°(终值为9.0°),近端继发弯Cobb角平均丢失4.1°(终值为10.0°);LIV倾斜角平均增加1.1°(终值为6.0°)。尽管存在一定程度的角度丢失,但上述三项指标末次随访值与术前基线相比,差异仍有统计学意义(P=0.004,P<0.001,P<0.001)。SA在末次随访时为0.7°±0.9°,与术前相比差异有统计学意义(P<0.001)。末次随访时C7PL-CSVL维持在1.2±0.5cm,未见冠状面失代偿(定义为C7PL-CSVL>2.0cm或较术后即时恶化>1cm)病例。结论:应用Dynesys系统行后路矫形内固定术治疗Risser征>Ⅲ级、Bending位矫正率>70%的Lenke 5型AIS可获得满意的即时矫形效果,且随访期内冠状面平衡参数维持良好。
英文摘要:
  【Abstract】 Objectives: To explore the impact of posterior corrective internal fixation with Dynesys system on the coronal balance of spine in Lenke type 5 adolescent idiopathic scoliosis(AIS) patients. Methods: A retrospective analysis was conducted on the imaging data of 13 patients with Lenke type 5 AIS(Risser sign>Ⅲ, correction rate in bending position>70%) who underwent posterior instrumentation with Dynesys system at our hospital from November 2019 to August 2024. Preoperative, postoperative 1 week(first follow-up), and final follow-up main curve Cobb angle, proximal secondary curve Cobb angle, shoulder angle(SA), lower instrumented vertebra(LIV) tilt angle, and C7PL-CSVL(distance between the C7 plumb line and the sacral midline plumb line) were measured and compared to analyze the influence of surgery at different postoperative time points on coronal parameters. Results: All 13 patients were reexamined within one week after operation; 11 patients completed the final follow-up, while two patients failed to complete the final follow-up due to personal reasons. The follow-up duration was 17.5±13.6 months(range: 6-60 months). One week post-surgery, the main curve Cobb angle decreased from 43.4°±9.1° pre-surgery to 5.9°±4.7°, with an average correction rate of 86.5%; the proximal secondary curve Cobb angle decreased from 22.3°±10.1° to 5.9°±5.8°, with an average correction rate of 73.8%. There were statistically significant differences in the above indicators between pre-surgery and 1 week post-surgery(P<0.001). C7PL-CSVL decreased from 2.3±1.2cm pre-surgery to 1.2±0.4cm one week post-surgery; LIV tilt decreased from 16.5°±4.6° pre-surgery to 4.9°±3.2° one week post-surgery, both differences were statistically significant(P<0.001). SA changed from 2.9°±1.8° pre-surgery to 2.4°±2.1° one week post-surgery, with no statistically significant difference(P=0.345). Final follow-up(n=11) compared with 1 week post-surgery, the main curve Cobb angle had an average loss of 3.1°(final value of 9.0°), and the proximal secondary curve Cobb angle had an average loss of 4.1°(final value of 10.0°); LIV tilt angle increased by an average of 1.1°(final value of 6.0°). Despite a certain degree of angle loss, the differences in the above three indicators at the final follow-up compared to the pre-surgery baseline were still statistically significant(P=0.004, P<0.001, P<0.001). SA was 0.7°±0.9° at the final follow-up, with a statistically significant difference compared to pre-surgery(P<0.001). C7PL-CSVL remained at 1.2±0.5cm at the final follow-up, and no cases of coronal plane decompensation(defined as C7PL-CSVL>2.0cm or deterioration>1cm compared to immediate post-surgery) were observed in this group. Conclusions: Posterior corrective internal fixation using Dynesys system in treating Lenke type 5 AIS with Risser sign>Ⅲ and correction rate in bending position>70% can achieve satisfactory immediate corrective effects, and the coronal plane balance parameters remain well-maintained during the follow-up period.
查看全文  查看/发表评论  下载PDF阅读器
关闭
function PdfOpen(url){ var win="toolbar=no,location=no,directories=no,status=yes,menubar=yes,scrollbars=yes,resizable=yes"; window.open(url,"",win); } function openWin(url,w,h){ var win="toolbar=no,location=no,directories=no,status=no,menubar=no,scrollbars=yes,resizable=no,width=" + w + ",height=" + h; controlWindow=window.open(url,"",win); } &et=9a5079e6cd494529e8f5dc9e6e3252857f1b0716c7595fe490c3b42848282b386aa7ee0d98220b84df314a0ed108e49db341b2e71f889024ba8b972d6099420f210fc3e152fbfd92dbf3afb29a90d66e9aebb3bba41556734d3fa53e7825088787f58fdf4174a40cc301c0fcc9c95feea9182eeadbfd99067299db19b5a802b0c264b81b50860386ccdd68dad6b2b18155d1b7fe491a4ae71a10bf5f83bb1d8b&pcid=3b2e4763797f121df1e5c0ba55cffa7b&cid=b38b646414cdcf7db2ea2d31acb25be6&jid=5fdf8640490760c406b420309027a8f7&yid=a76b0c4434fafe5bbe1e66b98fe1e513&aid=&vid=&iid=44c0b78492ce4b5d113d93466c25cbe4&sid=70f9df6409f18195233e4b5c4c42d086&eid=88e92b7c9a7765b19fdbadb1cc54e6c6&fileno=20260901&flag=1&is_more=0"> var my_pcid="3b2e4763797f121df1e5c0ba55cffa7b"; var my_cid="b38b646414cdcf7db2ea2d31acb25be6"; var my_jid="5fdf8640490760c406b420309027a8f7"; var my_yid="a76b0c4434fafe5bbe1e66b98fe1e513"; var my_aid="";