焦力刚,奚春阳,徐公平,周 磊,陈纪宝,闫景龙.下腰椎上关节突及峡部相关解剖结构的影像学测量[J].中国脊柱脊髓杂志,2012,(5):439-442. |
下腰椎上关节突及峡部相关解剖结构的影像学测量 |
The radiological measurement on the superior articular process and interarticular isthmus in lower lumbar vertebra |
投稿时间:2011-08-29 修订日期:2011-12-29 |
DOI:10.3969/j.issn.1004-406X.2012.5.439.3 |
中文关键词: 腰椎 上关节突 峡部 X线 测量 |
英文关键词:Lumbar vertebra Superior articular process Interarticular isthmus Radiography Measurement |
基金项目: |
|
摘要点击次数: 3625 |
全文下载次数: 2814 |
中文摘要: |
【摘要】 目的:通过影像学方法对下腰椎的上关节突及峡部相关解剖结构进行测量,观察新型腰椎后路植骨术术中安全操作范围及其与体重及身高的相关性。方法:搜集门诊体检25~40岁正常成年人腰椎正侧位X线片(腰椎序列正常,腰椎正、侧位片显示腰椎无侧凸、畸形、旋转,腰椎骨质无异常)男、女各120例,其中,男性身高157~190cm,平均173.63cm,体重50~95kg,平均76.61kg;女性身高150~174cm,平均162.17cm,体重45~80kg,平均59.07kg。用digimizer测量软件对L3~L5椎体正位片上上关节突的长度、宽度及侧位片上上关节突的深度,峡部深度、绝对深度,植骨床长度等进行测量。利用直线回归方程分析L3~L5各椎体上关节突长度、宽度、深度和峡部深度,绝对深度,植骨床长度等是否与身高体重具有相关性。结果:男性和女性L3~L5椎体上关节突长度、宽度、深度,峡部深度,绝对深度及植骨床长度平均为1.04±0.26cm和0.98±0.25cm、0.74±0.16cm和0.72±0.19cm、2.30±0.24cm和2.17±0.24cm,0.92±0.12cm和0.84±0.11cm,1.23±0.18cm和1.16±0.18cm,2.06±0.20cm和2.01±0.17cm。男性及女性的上关节突长度、宽度、深度及峡部深度,绝对深度与身高体重无明显相关性(P>0.05)。植骨床长度与身高具有显著相关性(P<0.01),与体重无明显相关性(P>0.05)。结论:通过影像学测量可以较为准确的获得下腰椎上关节突及峡部相关解剖学数值,为新型腰椎后路植骨术劈骨操作提供了一个较为可靠地数据支持。 |
英文摘要: |
【Abstract】 Objectives: To perform the radiological measurement on the superior articular process and interarticular isthmus in lower lumbar vertebra and to explore the safe zone in the procedure of bony graft in lumbar spine and its association with body weight and height. Methods: 120 males and 120 females 20-45 years old undergoing physical examination were reviewed retrospectively. L-Spine PA & LAT X-ray films were used for evaluation, those with lumbar scoliosis, deformity, rotation were excluded in this study. The height of male was 157~190cm with an average of 173.63cm; and that of female was 150-174cm with an average of 162.17cm; the weight of male and female was 50-95kg(average 76.61kg) and 45-80kg(average 59.07kg) respectively. The anatomical data including the length, width and depth of the superior articular process, interarticular isthmus depth, absolutely depth, the length of bone graft at L3-L5 level were measured by using Digimizer software and were analyzed by using the linear regressive equation. Results: The length, width and depth of superior articular process, the depth of interarticular, the absolutely depth and the length of bone graft was 1.04±0.26cm and 0.98±0.25cm, 0.74±0.16cm and 0.72±0.19cm, 2.30±0.24cm and 2.17±0.24cm, 0.92±0.12cm and 0.84±0.11cm, 1.23±0.18cm and 1.16±0.18cm, 2.06±0.20cm and 2.01±0.17cm for male and female respectively. The length, width and depth of superior articular process, the depth of interarticular and absolutely depth showed no relationship with height and weight (P>0.05), while the length of bone graft was associated significantly with height(P<0.01) rather than weight(P>0.05). Conclusions: The anatomical data of superior articular process and interarticular isthmus in lumbar spine acquired by radiographic measurement can be used to support the novel posterior lumbar spine fusion. |
查看全文 查看/发表评论 下载PDF阅读器 |
关闭 |
|
|
|